The High Effective and functioning of AirHorse series cooling type dryer

How the dryers works?The dryer is in fact divided
into three systems:heat exchanging,refrigeration and
electric control system.Compressed air enters the air-air
or air-water precooler for removing heat content,then
it enters the air or air heat exchanger and being cooled down to a lower temperature.After it enters the
evaporator,the air to refrigerant heat reduce the air
temperature down to 2-5℃(Dew point temp),the
moistura will be condensed into liquid,which will be
separated by separator and be drained off by the solenoid drain valve.In the mean time,low temperature air passes through the air to air heat exchanger,then goes to application after reaching designed temperature.

  • Strong cooling ability

    With high power supply refrigeration media compressor which can pre-cool it and exchange the heat and refrigerate again; therefore the air will 30% more than
    dryer than any other factory products.

  • High seperation effection

    High effective separator which can filtrate more than 99% of the water,oil and the solid impurity in the compressed air.

  • Water outlet stable and reliable

    Adopting the electron to outlet water automatically using valve and metal netting and its specially holding water method ensuring the reliability of the water outlet

  • High Inlet temperature

    With the pre-cooling system, using thickest copper heat-exchanging spare parts, could take up to 80 degrees hot air.

  • Low limitation temperature

    Using the high functioning evaporation system, itcould make the heat-exchange in large scale, and ensure the long staying and thorough heat-exchanging of the compressed air in the evaporation system. And also make the more compressed air into water and drying it.

  • Automatic controlling

    High effective refrigeration system which automatically control, adjusting high or low temperature and never stop working. It could always maintain the best performance.

  • Stable functioning

    Combination of Japanese ,Denmark and other famous brand accessories to ensure the product is maintained high quality.

The Flow-Chart

  • 1.Refrigeration Compressor
  • 2.Refrigeration High Voltage Meter
  • 3.Air-cooling condenser
  • 4.Water-cooling Condenser
  • 5.Repair Valve
  • 6.Filling Valve
  • 7.Dry Filter
  • 8.Eleceromagnetic Valve
  • 9.Refrigeration Window
  • 10.Expansion Valve
  • 11.Capillary
  • 12.Hot Air Bypass Valve
  • 13.Steamer
  • 14.Air-Moisture Separator
  • 15.Air thermal Exchanger
  • 16.Liquid-Air Separator
  • 17.Air-cooling Prepositive Cooler
  • 18.Water-cooling Prepositive Breaker
  • 19.High Voltage Protective Breaker
  • 20.Pressure Control Switch
  • 21.Auto Drain
  • 22.Cooling Water Filter
  • 23.Water Volume
    Adjustment Valve
  • 24.Excessive High Pressure
    Safety Load-releasing Valve
  • 25.Air Entry Pressure Meter
  • 26.Air Exit Pressure Meter
  • 27.Refrigeration Low-pressure Meter
  • Working condition and technical data
  • Inlet temperature:≤60℃
  • Ambient temp: ≤35℃
  • Cooling method:Air-cooling
  • Outlet temperature:1-10℃


The air-cooling flow chart DWT-7.5-300

The water-cooling flow chart DWT-300-3000


Refrigerated Compressed Air Dryer
Model AH-5SG AH-10SG AH-15SG AH-20SG AH-30SG AH-50G AH-60G AH-75G AH-100G AH-120G AH-150GF AH-200GF AH-250GF AH-300GF AH-400GF
Ambient temperature 25℃ 25℃ 25℃ 25℃ 25℃ 25℃ 25℃ 25℃ 25℃ 25℃ 25℃ 25℃ 25℃ 25℃ 25℃
Compressed air temperature at inlet ≤60℃ ≤60℃ ≤60℃ ≤60℃ ≤60℃ ≤60℃ ≤60℃ ≤60℃ ≤60℃ ≤60℃ ≤60℃ ≤60℃ ≤60℃ ≤60℃ ≤60℃
Cooling model Air-Cooling
Air flow (m3/min) 1.0 1.5 2.0 2.5 3.8 6.5 7.5 10.5 13.8 16.0 20.0 28.0 30.0 35.0 45.0
Air flow (CFM) 35.33568
90459364
53.00353
35689046
70.67137
80918728
88.33922
2614841
134.2756
18374558
229.6819
78798587
265.0176
67844523
371.0247
34982332
487.6325
08833922
565.3710
24734982
706.7137
80918728
989.3992
93286219
1060.070
67137809
1236.749
11660777
1590.106
00706714
Compressor power(KW) 0.32 0.43 0.51 0.73 0.92 1.38 1.38 1.78 2.57 2.57 2.94 4.4 4.8 5.5 7.35
Air inlet pressure(Mpa) 0.4--1.0 0.4--1.0 0.4--1.0 0.4--1.0 0.4--1.0 0.4--1.0 0.4--1.0 0.4--1.0 0.4--1.0 0.4--1.0 0.4--1.0 0.4--1.0 0.4--1.0 0.4--1.0 0.4--1.0
Loss of pressure(Mpa) ≤0.02 ≤0.02 ≤0.02 ≤0.02 ≤0.02 ≤0.02 ≤0.02 ≤0.02 ≤0.02 ≤0.02 ≤0.02 ≤0.02 ≤0.02 ≤0.02 ≤0.02
Dew point(℃) 2--5 2--5 2--5 2--5 2--5 2--5 2--5 2--5 2--5 2--5 2--5 2--5 2--5 2--5 2--5
Maximum pressure 13KG 13KG 13KG 13KG 13KG 13KG 13KG 13KG 13KG 13KG 13KG 13KG 13KG 13KG 13KG
Pipe diameter R1" R1" R1" R1 1/2" R1 1/2" R1 1/2" R1 1/2" R2 1/2" R2 1/2" R2 1/2" R3" R3" PN1.0DN80 PN1.0DN100 PN1.0DN100
Electricity(V/ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50
Dimension L 640 640 700 730 760 900 1020 1200 1200 1200 1400 1400 1580 1730 1980
(mm) W 380 380 390 420 450 500 610 600 600 600 730 730 900 995 995
H 710 710 730 760 970 1120 990 1120 1270 1270 1350 1350 1760 1840 2025
N.W.(KG) 40 45 50 60 80 110 123 175 202 225 315 421 508 633 860